Board: esp8266

esphome:
name: sp211
platform: ESP8266
board: esp8285
wifi:
ssid: !secret wifi_ssid
password: !secret wifi_password
# domain: !secret domain
# use_address: 192.168.6.52
# Enable fallback hotspot (captive portal) in case wifi connection fails
ap:
ssid: "${plug_name} Fallback Hotspot"
password: !secret fallback_password
captive_portal:
# Enable logging
logger:
# Enable Home Assistant API
api:
ota:
time:
- platform: homeassistant
id: homeassistant_time
substitutions:
plug_name: sp211
# Higher value gives lower watt readout
#current_res: "0.00520"
current_res: "0.00130"
# Lower value gives lower voltage readout
#voltage_div: "750"
voltage_div: "950"
# Enable Web server
web_server:
port: 80
sensor:
- platform: wifi_signal
name: "${plug_name} - WiFi Signal"
update_interval: 60s
- platform: uptime
name: "${plug_name} - Uptime"
icon: mdi:clock-outline
update_interval: 60s
- platform: hlw8012
sel_pin:
number: GPIO03
inverted: true
cf_pin: GPIO04
cf1_pin: GPIO05
current_resistor: ${current_res}
voltage_divider: ${voltage_div}
current:
name: "${plug_name} - Ampere"
unit_of_measurement: A
accuracy_decimals: 3
icon: mdi:flash-outline
voltage:
name: "${plug_name} - Volt"
unit_of_measurement: V
accuracy_decimals: 1
icon: mdi:flash-outline
power:
name: "${plug_name} - Watt"
unit_of_measurement: W
id: "${plug_name}_power"
icon: mdi:flash-outline
change_mode_every: 4
update_interval: 10s
- platform: total_daily_energy
name: "${plug_name} - Daily energy consumed"
power_id: "${plug_name}_power"
filters:
# Multiplication factor from W to kW is 0.001
- multiply: 0.001
unit_of_measurement: kWh
icon: mdi:clock-alert
text_sensor:
- platform: version
name: "${plug_name} - ESPHome Version"
status_led:
pin:
number: GPIO01
inverted: true
binary_sensor:
- platform: gpio
id: button1
internal: true
pin:
number: GPIO12
mode: INPUT_PULLUP
inverted: true
#on_state:
on_press:
- switch.toggle: relay1
- platform: gpio
id: button2
internal: true
pin:
number: GPIO00
mode: INPUT_PULLUP
inverted: true
#on_state:
on_press:
- switch.toggle: relay2
# Fix for overload bug in certain SP211 devices
- platform: gpio
id: gpio15_irq
pin: GPIO15
internal: true
output:
- platform: gpio
pin: GPIO02
inverted: true
id: led1
- platform: gpio
pin: GPIO13
inverted: true
id: led2
switch:
- platform: gpio
pin: GPIO14
id: relay1
restore_mode: RESTORE_DEFAULT_OFF
name: '${plug_name} - Switch 1'
icon: mdi:power-socket-eu
on_turn_on:
- output.turn_on: led1
on_turn_off:
- output.turn_off: led1
- platform: gpio
pin: GPIO16
id: relay2
restore_mode: RESTORE_DEFAULT_OFF
name: '${plug_name} - Switch 2'
icon: mdi:power-socket-eu
on_turn_on:
- output.turn_on: led2
on_turn_off:
- output.turn_off: led2
Edit this page on GitHub